Thermocouples / Double Wire Fast On

Termocouples_cift_telli_fast_on

Thermocouples Double Wire FAST ON

Thermocouple was developed with the purpose of providing the security of cooking and heating devices that work with gas. When the combination of two conductive metals is heated, a tension is created on the other edges. Thus gas tap magnet coil is magnetized and gas is ignited by opening the gas path. When the flame is extinguished by any reason, gas path is closed and safety is provided

Thermocouples developed and produced by Yesa Elektronik are designed for cooking and heating devices that work with gas. It provides the magnetization 1 second after the start of gas passage and cuts out the gas 11-13 seconds after the extinguishing of the device. These measures are the upper values requested by the norms.

In line with the customer requests; our product types that are developed as a result of R&D studies are produced for all kinds of valve, burner and gas types.
Based on their usage area and burner types; with pipe, one wires, double wires. Based on the valve connection; fast-on, coaxial, nut types are available.

 

3D Image TECNICAL IMAGE TECNICAL PROPERTIES

Thermocouples Double Wire Fast On 3D Image

Termocouples Double Wire Fast On 3D
Termocouples Double Wire Fast On 3D

Thermocouples Double Wire Fast On Tecnical Image

Termocouples Double Wire Fast On Teknik
Termocouples Double Wire Fast On Teknik

Thermocouples Double Wire Fast On Tecnical Properties

  • - Switch on time 1 Sec
  • - Switch off time 9-18 Sec
  • - Temperature on head Max 1150 °C
  • - Temperature on connectors Max 230 °C
  • - Thermocouple temperature 120 °C
  • - Temperature voltage 440-800 °C 15-30 mV